Resultados 1 - 20 de 94
Filtrar
1.
EClinicalMedicine ; 67: 102391, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38274117

RESUMEN

Background: Clinical appearance and high-frequency ultrasound (HFUS) are indispensable for diagnosing skin diseases by providing internal and external information. However, their complex combination brings challenges for primary care physicians and dermatologists. Thus, we developed a deep multimodal fusion network (DMFN) model combining analysis of clinical close-up and HFUS images for binary and multiclass classification in skin diseases. Methods: Between Jan 10, 2017, and Dec 31, 2020, the DMFN model was trained and validated using 1269 close-ups and 11,852 HFUS images from 1351 skin lesions. The monomodal convolutional neural network (CNN) model was trained and validated with the same close-up images for comparison. Subsequently, we did a prospective and multicenter study in China. Both CNN models were tested prospectively on 422 cases from 4 hospitals and compared with the results from human raters (general practitioners, general dermatologists, and dermatologists specialized in HFUS). The performance of binary classification (benign vs. malignant) and multiclass classification (the specific diagnoses of 17 types of skin diseases) measured by the area under the receiver operating characteristic curve (AUC) were evaluated. This study is registered with www.chictr.org.cn (ChiCTR2300074765). Findings: The performance of the DMFN model (AUC, 0.876) was superior to that of the monomodal CNN model (AUC, 0.697) in the binary classification (P = 0.0063), which was also better than that of the general practitioner (AUC, 0.651, P = 0.0025) and general dermatologists (AUC, 0.838; P = 0.0038). By integrating close-up and HFUS images, the DMFN model attained an almost identical performance in comparison to dermatologists (AUC, 0.876 vs. AUC, 0.891; P = 0.0080). For the multiclass classification, the DMFN model (AUC, 0.707) exhibited superior prediction performance compared with general dermatologists (AUC, 0.514; P = 0.0043) and dermatologists specialized in HFUS (AUC, 0.640; P = 0.0083), respectively. Compared to dermatologists specialized in HFUS, the DMFN model showed better or comparable performance in diagnosing 9 of the 17 skin diseases. Interpretation: The DMFN model combining analysis of clinical close-up and HFUS images exhibited satisfactory performance in the binary and multiclass classification compared with the dermatologists. It may be a valuable tool for general dermatologists and primary care providers. Funding: This work was supported in part by the National Natural Science Foundation of China and the Clinical research project of Shanghai Skin Disease Hospital.

2.
J Ultrasound Med ; 43(1): 151-160, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37812196

RESUMEN

OBJECTIVES: To investigate whether the integration of high-frequency ultrasound (HFUS) to routine clinical examinations could improve diagnostic performance and management decision for pigmented skin tumors. METHODS: Three general practitioners trained previously and a dermatologist independently assessed pigmented skin tumors and rendered management decision based on clinical examinations alone or clinical examinations integrating HFUS. RESULTS: After integrating HFUS, the diagnostic area under the curve (AUC) (0.658-0.693 versus 0.848, all P < .05) and specificity (46.6-58.6% versus 89.7%, all P < .05) for pigmented skin malignancies were improved for general practitioners, meanwhile unnecessary biopsy rate reduced (42.9-53.6% versus 10.7%, P < .001). To the dermatologist, the diagnostic AUC (0.822 versus 0.949, P < .001), sensitivity (81.7% versus 96.7%, P = .012) and specificity (0.828 versus 0.931, P = .031) improved significantly, meanwhile both missed biopsy rate (14.5% versus 4.8%, P = .031) and unnecessary biopsy rate (19.6% versus 7.1%, P = .016) decreased. Additionally, the diagnostic performance of the general practitioner with integrating HFUS could be comparable with the dermatologist based on clinical examinations alone (all P > .05). CONCLUSIONS: As a complementary tool of clinical examinations, HFUS could help physicians differentiate pigmented skin malignancies and manage decision.


Asunto(s)
Melanoma , Neoplasias Cutáneas , Humanos , Sensibilidad y Especificidad , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/patología , Biopsia , Ultrasonografía
3.
Abdom Radiol (NY) ; 49(3): 942-957, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38102443

RESUMEN

PURPOSE: To explore the feasibility of a 5G-based telerobotic ultrasound (US) system for providing qualified abdominal US services on a rural island. METHODS: This prospective study involved two medical centers (the tele-radiologist site's hospital and the patient site's hospital) separated by 72 km. Patients underwent 5G-based telerobotic US by tele-radiologists and conventional US by on-site radiologists from September 2020 to March 2021. The clinical feasibility and diagnostic performance of the 5G-based telerobotic abdominal US examination were assessed based on safety, duration, image quality, diagnostic findings, and questionnaires. RESULTS: A total of 401 patients (217 women and 184 men; mean age, 54.96 ± 15.43 years) were enrolled. A total of 90.1% of patients indicated no discomfort with the telerobotic US examination. For the examination duration, telerobotic US took longer than conventional US (12.54 ± 3.20 min vs. 7.23 ± 2.10 min, p = 0.001). For image quality scores, the results of the two methods were similar (4.54 ± 0.63 vs. 4.57 ± 0.61, p = 0.112). No significant differences were found between the two methods in measurements for the aorta, portal vein, gallbladder, kidney (longitudinal diameter), prostate, and uterus; however, telerobotic US underestimated the transverse diameter of the kidney (p < 0.05). A total of 504 positive results, including 31 different diseases, were detected. Among them, 455 cases were identified by the two methods; 17 cases were identified by telerobotic US only; and 32 cases were identified by conventional US only. There was good consistency in the diagnosis of 29 types of disease between the two methods (κ = 0.773-1.000). Furthermore, more than 90% of patients accepted the telerobotic US examination and agreed to pay additional fees in future. CONCLUSION: The 5G-based telerobotic US system can expand access to abdominal US services for patients in rural areas, thereby reducing health care disparities.


Asunto(s)
Robótica , Masculino , Humanos , Femenino , Adulto , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Robótica/métodos , Ultrasonografía , Abdomen/diagnóstico por imagen , Riñón
4.
Diagnostics (Basel) ; 13(18)2023 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-37761299

RESUMEN

BACKGROUND: Rural general practitioners (GPs) have insufficient diagnostic information to deal with complex clinical scenarios due to the inequality in medical imaging resources in rural and remote communities. The objective of this study is to explore the value of a tele-mentored handheld ultrasound (tele-HHUS) system, allowing GPs to provide ultrasound (US) services in rural and remote communities. METHODS: Overall, 708 patients underwent tele-HHUS examination between March and October 2021 and March and April 2022 across thirteen primary hospitals and two tertiary-care general hospitals. All US examinations were guided and supervised remotely in real time by US experts more than 300 km away using the tele-HHUS system. The following details were recorded: location of tele-HHUS scanning, primary complaints, clinical diagnosis, and US findings. The recommendations (referral or follow-up) based on clinical experience alone were compared with those based on clinical experience with tele-HHUS information. RESULTS: Tele-HHUS examinations were performed both in hospital settings (90.6%, 642/708) and out of hospital settings (9.4%, 66/708). Leaving aside routine physical examinations, flank pain (14.2%, 91/642) was the most common complaint in inpatients, while chest distress (12.1%, 8/66) and flank discomfort (12.1%, 8/66) were the most common complaints in out-of-hospital settings. Additionally, the referral rate increased from 5.9% to 8.3% (kappa = 0.202; p = 0.000). CONCLUSIONS: The tele-HHUS system can help rural GPs perform HHUS successfully in remote and rural communities. This novel mobile telemedicine model is valuable in resource-limited areas.

5.
Skin Res Technol ; 29(9): e13464, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37753674

RESUMEN

BACKGROUND: It is unknown whether high-frequency ultrasound (HFUS) can evaluate invisible subcutaneous lesions. We aimed to investigate the diagnostic value of HFUS in invisible subcutaneous lesions. METHOD: Patients with invisible subcutaneous lesions were prospectively recruited from two centres. Before undergoing biopsy or surgery, each lesion was independently evaluated by two clinicians. One provides a clinical diagnosis by only clinical examination and the other provides an integrated diagnosis by combining clinical examination and HFUS information. Diagnoses were classified as correct, wrong, and indeterminate. A total of 391 lesions from 355 patients were enrolled, including 225 epidermoid cysts, 77 lipomas, 25 pilomatrixomas, 21 haemangiomas, 19 dermatofibromas, 11 dermatofibrosarcoma protuberans (DFSP), 7 neurofibromas, and 6 leiomyomas. Using pathological results as the gold standard, diagnostic performance was compared. RESULTS: The number of correct diagnoses increased from 185 (47.3%) by clinical examination alone to 316 (80.8%) after the addition of HFUS (P < 0.05). Meanwhile, the indeterminate diagnosis rate decreased from 143 (36.6%) to 10 (2.6%). Using HFUS, the accuracy improved significantly for epidermoid cysts (59.6% vs. 86.7%), lipomas (50.6% vs. 94.8%), pilomatrixomas (0% vs. 48.0%), haemangiomas (23.8% vs. 57.1%), and DFSPs (0% vs. 81.8%) (all p < 0.05). However, HFUS did not significantly improve the diagnostic accuracy of dermatofibromas (15.8% vs. 21.1%, p > 0.999), neurofibromas (42.9% vs. 71.4%, p = 0.625), or leiomyomas (16.7% vs. 100%, p = 0.063). CONCLUSION: Combining HFUS and clinical examination can generally improve the diagnostic accuracy and decrease the indeterminacy of invisible subcutaneous lesions, especially epidermoid cysts, lipomas, pilomatrixomas, haemangiomas, and DFSPs. However, for some rare lesions, HFUS cannot provide useful information.


Asunto(s)
Quiste Epidérmico , Enfermedades del Cabello , Hemangioma , Histiocitoma Fibroso Benigno , Leiomioma , Lipoma , Neurofibroma , Pilomatrixoma , Neoplasias Cutáneas , Humanos , Quiste Epidérmico/diagnóstico por imagen , Hemangioma/diagnóstico por imagen , Neoplasias Cutáneas/diagnóstico por imagen
7.
J Ultrasound Med ; 42(9): 1941-1950, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36896489

RESUMEN

OBJECTIVES: This study was aimed to evaluate the diagnostic performance of ultrasound (US) in differentiating trichilemmal cysts (TCs) from epidermoid cysts (ECs). METHODS: Based on clinical and ultrasound features, a prediction model was established and validated. 164 cysts in the pilot cohort and another 69 in the validation cohort diagnosed with TCs or ECs histopathologically were evaluated. The same radiologist performed all ultrasound examinations. RESULTS: For clinic features, TCs tended to occur in females compared with ECs (66.7 vs 28.5%; P < .001). In addition, TCs were prone to occur in the hairy area compared with ECs (77.8 vs 13.1%; P < .001). For ultrasound features, the internal hyperechogenicity and cystic change were more likely to appear in TCs in comparison with ECs (92.6 vs 25.5%; P < .001; 70.4 vs 23.4%; P < .001, respectively). Upon the features mentioned above, a prediction model was established with the areas under the receiver operating characteristic curves of 0.936 and 0.864 in the pilot and validation cohorts, respectively. CONCLUSIONS: US is promising for differentiating TCs from ECs and is valuable for their clinical management.


Asunto(s)
Quiste Epidérmico , Femenino , Humanos , Quiste Epidérmico/diagnóstico por imagen , Ultrasonografía , Diagnóstico Diferencial
8.
Diagnostics (Basel) ; 13(3)2023 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-36766467

RESUMEN

OBJECTIVE: Ultrasound (US) plays an important role in the diagnosis and management of breast diseases; however, effective breast US screening is lacking in rural and remote areas. To alleviate this issue, we prospectively evaluated the clinical availability of 5G-based telerobotic US technology for breast examinations in rural and remote areas. METHODS: Between September 2020 and March 2021, 63 patients underwent conventional and telerobotic US examinations in a rural island (Scenario A), while 20 patients underwent telerobotic US examination in a mobile car located in a remote county (Scenario B) in May 2021. The safety, duration, US image quality, consistency, and acceptability of the 5G-based telerobotic US were assessed. RESULTS: In Scenario A, the average duration of the telerobotic US procedure was longer than that of conventional US (10.3 ± 3.3 min vs. 7.6 ± 3.0 min, p = 0.017), but their average imaging scores were similar (4.86 vs. 4.90, p = 0.159). Two cases of gynecomastia, one of lactation mastitis, and one of postoperative breast effusion were diagnosed and 32 nodules were detected using the two US methods. There was good interobserver agreement between the US features and BI-RADS categories of the identical nodules (ICC = 0.795-1.000). In Scenario B, breast nodules were detected in 65% of the patients using telerobotic US. Its average duration was 10.1 ± 2.3 min, and the average imaging score was 4.85. Overall, 90.4% of the patients were willing to choose telerobotic US in the future, and tele-sonologists were satisfied with 85.5% of the examinations. CONCLUSION: The 5G-based telerobotic US system is feasible for providing effective breast examinations in rural and remote areas.

9.
Eur Radiol ; 33(6): 3943-3953, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36853346

RESUMEN

OBJECTIVE: To identify patients in the subclinical psoriatic arthritis (Sub-PsA) phase by ultrasound (US) and provide a solution to screen them. METHODS: A total of 490 participants with moderate-to-severe psoriasis were evaluated. Among them, 384 participants without arthritis symptoms were enrolled into the silent psoriasis group and 106 participants with arthritis symptoms, called prodromal/active PsA phase, were enrolled into the clinical PsA group. Another 80 non-psoriasis participants were enrolled into the control group. Each participant received clinical assessments and US examinations of 60 joints, 38 tendons, and 40 entheses. We compared the incidences of synovio-enthesitis, synovitis, tenosynovitis, erosion, and dactylitis detected on US among the three groups. Subsequently, on the basis of significant US findings, we distinguished Sub-PsA from psoriasis alone (PsO) in the silent psoriasis group and analyzed the clinical characteristics, mainly including basic clinical characteristics, body surface area (BSA), and Psoriasis Area and Severity Index (PASI) score. RESULTS: Only synovio-enthesitis significantly differed between the control group and the silent psoriasis group (1.3% vs. 16.1%, p < 0.001). The knee was the most commonly involved site of synovio-enthesitis (79.0%). Taking synovio-enthesitis as the standard, 16.1% of silent psoriasis participants and 12.7% of all psoriasis participants were in the Sub-PsA phase. Furthermore, there were no differences in BSA and PASI among the three phases of PsO, Sub-PsA, and prodromal/active PsA. CONCLUSIONS: Since the psoriasis patients in Sub-PsA phase was as high as 12.7% in all patients with moderate-to-severe psoriasis, US-detected synovio-enthesitis was recommended routinely for screening them regardless of arthritis symptoms, especially in the lower limbs. KEY POINTS: • Synovio-enthesitis on ultrasound was significantly associated with subclinical psoriatic arthritis, especially in the lower limbs. • Routine ultrasound evaluation could help screen psoriasis patients in the subclinical psoriatic arthritis phase, which was as high as 12.7% in all psoriasis patients.


Asunto(s)
Artritis Psoriásica , Entesopatía , Psoriasis , Tenosinovitis , Humanos , Artritis Psoriásica/complicaciones , Artritis Psoriásica/diagnóstico por imagen , Psoriasis/complicaciones , Psoriasis/diagnóstico por imagen , Ultrasonografía , Entesopatía/complicaciones , Índice de Severidad de la Enfermedad
10.
Dermatology ; 239(4): 572-583, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36731445

RESUMEN

BACKGROUND: The similar visual appearance of superficial basal cell carcinoma (sBCC) and Bowen's disease (BD) may cause confusion for diagnosis. OBJECTIVE: The aim of the study was to investigate the value of ultra-high-frequency ultrasound (uHFUS) in differentiating sBCC from BD. MATERIALS AND METHODS: This prospective study included a pilot cohort of 110 patients (73 BDs and 37 sBCCs) from November 2016 to October 2020 and a validation cohort of 42 patients (30 BDs and 12 sBCCs) from July 2021 to December 2021. Clinical and uHFUS features of pathologically confirmed sBCC and BD were assessed. A predictive model was developed based on the uHFUS features of the pilot cohort. Subsequently, the model was validated and compared with clinical diagnosis in the validation cohort. RESULTS: uHFUS features with significant differences between sBCC and BD included lesion surface, skin layer involvement, hyperkeratosis, and hyperechoic spots (all p < 0.05). A prediction model based on the above features was established to identify sBCC and BD in the pilot and validation cohorts with areas under the curve (AUC) of 0.908 and 0.923, sensitivity of 82.3% and 83.3%, specificity of 91.9% and 91.7%, and accuracy of 85.5% and 85.7%, respectively, which were significantly higher than those obtained by clinical diagnosis based on photographic pictures of lesions, with the AUC of 0.692, sensitivity of 63.3%, specificity of 75.3%, and accuracy of 66.7% (all p < 0.05). CONCLUSION: uHFUS provides detailed internal features of sBCC and BD, which facilitates the differentiation between sBCC and BD, and its diagnostic performance is superior to clinical diagnosis.


Asunto(s)
Enfermedad de Bowen , Carcinoma Basocelular , Neoplasias Cutáneas , Humanos , Neoplasias Cutáneas/patología , Estudios Prospectivos , Enfermedad de Bowen/diagnóstico por imagen , Carcinoma Basocelular/patología , Diferenciación Celular
12.
Eur Radiol ; 33(6): 4007-4015, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36648552

RESUMEN

OBJECTIVES: We assessed muscle mass and function using ultrasound (US) and shear wave elastography (SWE) for sarcopenia in elderly patients with type 2 diabetes. METHODS: There were 84 patients with type 2 diabetes enrolled in this study; of these, 30 had sarcopenia and 54 did not. We measured appendicular skeletal muscle mass index (ASMI), handgrip strength, calf circumference, 6-m walking speed, and 5-time chair stand test. All patients were in the supine position with their knees in straight and bent poses in turn. The US-derived thickness (Tstraight, Tbent), cross-sectional area (CSAstraight, CSAbent), and SWE (SWEstraight, SWEbent) of the rectus femoris muscle (RFM) were measured and the differences (ΔT, ΔCSA, ΔSWE) were calculated. We assessed the correlations of clinical indicators with US and SWE features. We then compared the clinical indicators and US and SWE features between patients with and without sarcopenia to determine independent predictors. Diagnostic models were established based on these independent predictors. RESULTS: The ASMI was correlated with Tbent (r = 0.57, p < 0.001) and CSAbent (r = 0.50, p < 0.001). Handgrip strength was correlated with Tbent (r = 0.53, p < 0.001) and CSAbent (r = 0.51, p < 0.001). Between patients with and without sarcopenia, the indicators of age, ΔCSA, and ΔSWE were statically different (all p ≤ 0.001). Based on these results, a diagnostic model for sarcopenia was established with 83.3% sensitivity, 83.3% specificity, and 83.3% accuracy. CONCLUSIONS: In elderly people with type 2 diabetes, sarcopenia patients had smaller muscle CSA and less stiffness than non-sarcopenia patients. US and SWE might be useful to screen them. KEY POINTS: • Sarcopenia is common in elderly people with type 2 diabetes. • Ultrasound and shear wave elastography might be useful methods for quantitatively assessing muscle mass and strength. • Ultrasound and shear wave elastography might be useful methods for screening sarcopenia in elderly patients with type 2 diabetes.


Asunto(s)
Diabetes Mellitus Tipo 2 , Diagnóstico por Imagen de Elasticidad , Sarcopenia , Humanos , Anciano , Diagnóstico por Imagen de Elasticidad/métodos , Fuerza de la Mano , Diabetes Mellitus Tipo 2/complicaciones , Ultrasonografía , Sarcopenia/complicaciones , Sarcopenia/diagnóstico por imagen , Músculo Cuádriceps , Músculo Esquelético/diagnóstico por imagen
13.
Clin Hemorheol Microcirc ; 82(3): 217-230, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35848013

RESUMEN

PURPOSE: To evaluate a computer-aided diagnosis (CAD) technique in predicting malignancy for cytologically indeterminate thyroid nodules (TNs) as compared with different experienced radiologists. METHOD: 436 patients with 436 cytologically indeterminate TNs on fine-needle aspiration cytology (FNAC) were included and all were confirmed by surgical pathology. They were retrospectively analyzed with respect to ultrasound (US) characteristics using a commercially available CAD system (AmCAD-UT; AmCad BioMed, Taiwan, China) and reviewed by one junior and one senior radiologists.The CAD system and different experienced radiologists stratified the risk of malignancy using ACR TI-RADS category. The diagnostic performance by different experienced radiologists independently and after consulting the CAD (different experienced radiologists + CAD) and by the CAD alone were compared. RESULTS: The different experienced radiologists showed significantly higher specificities than the CAD system alone. The combination of radiologist and CAD system showed improved diagnostic performance with an AUC (Area under the curve) of 0.740 in the senior radiologist and 0.677 in the junior radiologist, as compared with CAD (AUC: 0.585) alone (all P < 0.05). The combination of senior radiologist and CAD system had the highest diagnostic performance (AUC: 0.740) and specificity (68.9%) compared to the others (all P < 0.05). CONCLUSION: The CAD system may play the potential role as a decision-making assistant alongside radiologists for differential diagnosis of TNs with indeterminate cytology.


Asunto(s)
Neoplasias de la Tiroides , Nódulo Tiroideo , Humanos , Nódulo Tiroideo/patología , Neoplasias de la Tiroides/patología , Sensibilidad y Especificidad , Estudios Retrospectivos , Ultrasonografía/métodos , Radiólogos , Computadores
14.
Ultrasonography ; 41(4): 650-660, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35773182

RESUMEN

PURPOSE: This study investigated the value of synchronous tele-ultrasonography (TUS) for naive operators in thyroid ultrasonography (US) examinations. METHODS: Ninety-seven patients were included in this prospective, parallel-controlled trial. Thyroid scanning and diagnosis were completed by resident A independently, resident B with guidance from a US expert through synchronous TUS, and an on-site US expert. The on-site expert's findings constituted the reference standard. Two other off-site US experts analyzed all data in a blind manner. Inter-operator consistency between the two residents and the on-site US expert for thyroid size measurements, nodule measurements, nodule features, American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) categories, and image quality was compared. Two questionnaires were completed to evaluate the clinical benefit. RESULTS: Resident B detected more nodules consistent with the on-site expert than resident A did (89.4% vs. 56.5%, P<0.001). Resident B achieved excellent consistency with the on-site expert in terms of ACR TI-RADS categories, nodule composition, shape, echogenic foci, and vascularity (all intra-class correlation coefficients [ICCs] >0.75), while resident A achieved lower consistency in ACR TI-RADS categories, composition, echogenicity, margin, echogenic foci, and vascularity (all ICCs 0.40-0.75). Residents A and B had excellent consistency in target nodule measurements (all ICCs >0.75). Resident B achieved better performance than resident A for gray values, time gain compensation, depth, color Doppler adjustment, and the visibility of key information (all P<0.05). Furthermore, 61.9% (60/97) of patients accepted synchronous TUS, and 59.8% (58/97) patients were willing to pay for it. CONCLUSION: Synchronous TUS can help inexperienced residents achieve comparable thyroid diagnostic capability to a US expert.

15.
Endocrine ; 76(3): 620-634, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35182363

RESUMEN

PURPOSE: To evaluate the feasibility of a 5G-based telerobotic ultrasound (US) system for thyroid examination on a rural island. METHODS: From September 2020 to March 2021, this prospectively study enrolled a total of 139 patients (average age, 58.6 ± 12.7 years) included 33 males and 106 females, who underwent 5G-based telerobotic thyroid US examination by a tele-doctor at Shanghai Tenth People's Hospital and a conventional thyroid US examination at Chongming Second People's Hospital 84 km away. The clinical feasibility of 5G-based telerobotic US for thyroid examination were evaluated in terms of safety, duration, US image quality, diagnostic results, and questionnaire survey. RESULTS: 92.8% of patients had no examination-related complaints. The average duration of the 5G-based telerobotic US examination was similar as that of conventional US examination (5.57 ± 2.20 min vs. 5.23 ± 2.1 min, P = 0.164). The image quality of telerobotic US correlated well with that of conventional US (4.63 ± 0.60 vs. 4.65 ± 0.61, P = 0.102). There was no significant difference between two types of US examination methods for the diameter measurement of the thyroid, cervical lymph nodes, and thyroid nodules. Two lymphadenopathies and 20 diffuse thyroid diseases were detected in two types of US methods. 124 thyroid nodules were detected by telerobotic US and 127 thyroid nodules were detected by conventional US. Among them, 122 were the same thyroid nodules. In addition, there were good consistency in the US features (component, echogenicity, shape, and calcification) and ACR TI-RADS category of the same thyroid nodules between telerobotic and conventional US examinations (ICC = 0.788-0.863). 85.6% of patients accepted the telerobotic US, and 87.1% were willing to pay extra fee for the telerobotic US. CONCLUSION: The 5G-based telerobotic US system can be a routine diagnostic tool for thyroid examination for patients on a rural island.


Asunto(s)
Robótica , Nódulo Tiroideo , Anciano , China , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Ultrasonografía/métodos
16.
J Ultrasound Med ; 41(2): 389-400, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33856069

RESUMEN

OBJECTIVES: Pathological invasion level of extramammary Paget disease (EMPD) is strongly related with its risk staging, treatment, and prognosis. However, the current evaluation before treatments fails to evaluate pathological invasion level of EMPD. High-frequency ultrasound (HFUS) may play a key role to solve this problem. The purpose was to explore the performance of HFUS in the evaluation of pathological invasion level of EMPD. METHODS: Sixty pathologically proven EMPD patients were retrospectively enrolled and divided into 2 groups as follows: in situ in the epidermis (IE) (n = 42) and invasion into the dermis or subcutaneous (ID) (n = 18) groups. Clinical and HFUS features were compared between the 2 groups. RESULTS: Between the 2 groups, HFUS features (lesion shape, internal echogenicity and echotexture, surface shape, epidermal hyperechoic layer on the surface, the "pseudopod sign", and color Doppler ultrasound features) and clinical features were comparable (all P >.05). Tumor growth pattern significantly differed between the 2 groups (P <.05). Infiltration depth was significantly deeper for the ID group than the IE group (P <.05). With a cutoff value of 1.55 mm for infiltration depth, the area under the receiver operating characteristic curve was 0.833. CONCLUSIONS: HFUS features of tumor growth pattern and infiltration depth may contribute to the assessment of invasion level of EMPD.


Asunto(s)
Enfermedad de Paget Extramamaria , Neoplasias Cutáneas , Humanos , Enfermedad de Paget Extramamaria/diagnóstico por imagen , Pronóstico , Estudios Retrospectivos , Neoplasias Cutáneas/diagnóstico por imagen , Ultrasonografía
17.
Skin Res Technol ; 28(3): 410-418, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34923684

RESUMEN

BACKGROUND: The similar visual appearance of high-risk basal cell carcinoma (BCC) and cutaneous squamous cell carcinoma (cSCC) may cause confusion for diagnosis. High-frequency ultrasound (HFUS) may provide additional intralesional information and thus help to distinguish them. METHOD: In this retrospective study, we analyzed the clinical characteristics, HFUS grayscale, and color Doppler flow imaging (CDFI) features of pathologically confirmed high-risk BCC and cSCC lesions (n = 65 vs n = 68). Subsequently, discrimination models based on the significant HFUS features were established. RESULTS: Between high-risk BCC and cSCC lesions, the HFUS grayscale features of the lesion size (10.0 mm vs 17.4 mm), thickness (3.1 mm vs 5.9 mm), internal hyperechoic spots (80.0% vs 23.5%), and posterior acoustic shadowing (16.9% vs 66.2%) were statistically different (all p < 0.001). As for the CDFI features, high-risk BCC lesions mainly appeared as pattern II (47.7%), while cSCC lesions mainly appeared as pattern III (66.2%). Based on the above five features, an optimal discrimination model was established with a sensitivity of 91.2%, a specificity of 87.7%, and an accuracy of 89.5%. CONCLUSION: HFUS features, including size, thickness, internal hyperechoic spots, posterior acoustic shadowing, and Doppler vascularity pattern, are useful for differential diagnosis between high-risk BCC and cSCC.


Asunto(s)
Carcinoma Basocelular , Carcinoma de Células Escamosas , Neoplasias Cutáneas , Carcinoma Basocelular/diagnóstico por imagen , Carcinoma Basocelular/patología , Carcinoma de Células Escamosas/diagnóstico por imagen , Humanos , Estudios Retrospectivos , Neoplasias Cutáneas/diagnóstico por imagen , Neoplasias Cutáneas/patología , Ultrasonografía/métodos
18.
Clin Hemorheol Microcirc ; 81(1): 33-45, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34958011

RESUMEN

BACKGROUND: Ultrasound-guided fine-needle aspiration (US-FNA) is the most accurate method for preoperative diagnosis of thyroid nodules, but how to deal with false negative results? OBJECTIVE: This study aimed to find preoperative diagnosis methods including Conventional Ultrasound (CUS), Shear Wave Elastography (SWE) and BRAF V600E testing to differentiate false negative nodules. METHODS: Forty-nine nodules in 49 patients with benign FNA results and pathological diagnoses were included. CUS and SWE features were evaluated. BRAF V600E analysis was performed after FNA. Diagnostic performances of three methods were analyzed in predicting malignancy in benign FNA results. RESULTS: Twenty-seven of 49 nodules were malignant, and 22 nodules were benign. Hypoechogenicity, taller-than-wider, irregular boundary, microcalcification, SWE max, SWE mean and BRAF V600E mutation were risk factors for malignancy. All 7 malignant nodules with BRAF V600E mutations and 18 of 20 malignant nodules without BRAF V600E mutations have two or more suspicious CUS features. Six of 7 malignant nodules with BRAF V600E mutations and 16 of 20 malignant nodules without BRAF V600E mutations had SWE mean value greater than the cut-off value. CONCLUSIONS: CUS, SWE and BRAF V600E were diagnostic tools for malignancy in FNA benign nodules. Further clinical decisions should be considered for nodules with two or more suspicious CUS features and SWE parameters greater than cut-off values whether BRAF V600E is mutational or not.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Neoplasias de la Tiroides , Nódulo Tiroideo , Biopsia con Aguja Fina/métodos , Diagnóstico por Imagen de Elasticidad/métodos , Humanos , Proteínas Proto-Oncogénicas B-raf/genética , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/genética , Neoplasias de la Tiroides/patología , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/genética , Ultrasonografía
19.
Ultrasonography ; 41(2): 307-316, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34794212

RESUMEN

PURPOSE: This prospective study explored the value of synchronous tele-ultrasound (US) to aid doctors inexperienced in US with breast US examinations. METHODS: In total, 99 patients were enrolled. Two trainee doctors who were inexperienced in US (trainee A [TA] and trainee B [TB]) and one doctor who was an expert in US completed the US examinations sequentially. TA completed the US examinations independently, while TB was instructed by the expert using synchronous tele-US. Subsequently, the expert performed on-site US examinations in person. Separately, they selected the most clinically significant nodule as the target nodule. Consistency with the expert and image quality were compared between TA and TB to evaluate tele-US. Furthermore, TB and the patients evaluated tele-US through questionnaires. RESULTS: TB demonstrated higher consistency with the expert in terms of target nodule selection than TA (93.3% vs. 63.3%, P<0.001). TB achieved good inter-observer agreement (ICC, >0.75) with the expert on five US features (5/9, 55.6%), while TA only did so for one (1/9, 11.1%) (P=0.046). TB's image quality was higher than TA's in gray value, time gain compensation, depth, color Doppler adjustment, and the visibility of key information (P=0.018, P<0.001, P<0.001, P=0.033, and P=0.006, respectively). The comprehensive assessment score was higher for TB than for TA (3.96±0.82 vs. 3.09±0.87, P<0.001). Tele-US was helpful in 69.7% of US examinations and had a training effect in 68.0%. Furthermore, 63.6% of patients accepted tele-US and 60.6% were willing to pay. CONCLUSION: Tele-US can help doctors inexperienced in US to perform breast US examinations.

20.
Ann Transl Med ; 9(18): 1444, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34733996

RESUMEN

BACKGROUND: To evaluate whether MicroPure imaging, an ultrasound (US) image-processing technique with computer-aided analysis, can quantitatively detect crystal dissolution during urate-lowering therapy (ULT) in gout. METHODS: This was a prospective study of gout patients requiring ULT. The first metatarsophalangeal joints were examined using US and MicroPure before and after 3 months of ULT. Elementary lesions of gout, including the double contour sign (DCS), aggregates, tophi, erosion, and other US features were recorded at baseline and 3 months. MicroPure imaging features were automatically calculated by a self-developed software. Patients were divided into goal-achieved and goal-not-achieved groups according to their urate levels at 3 months. The US and MicroPure imaging features of the two groups were analyzed at baseline and 3 months. RESULTS: A total of 55 consecutive patients were enrolled (25: goal-achieved group; 30: goal-not-achieved group). US findings demonstrated that the power Doppler signal grade decreased at 3 months, regardless of the group (both P<0.05). From baseline to 3 months, tophi size and the DCS reduced in the goal-achieved group (both P<0.05), while the US aggregate features showed no difference (P=0.250). However, on the MicroPure imaging, the number and density of aggregates at 3 months decreased in the goal-achieved group (both P<0.05). There were no significant changes at 3 months in any of the MicroPure imaging features in the goal-not-achieved group (all P>0.05). CONCLUSIONS: In comparison with B-mode US, computer-aided MicroPure imaging can sensitively and quantitatively detect aggregate dissolution during effective ULT after only 3 months of treatment.

SELECCIÓN DE REFERENCIAS